Specifications
| PM3 | Measuring range | Best accuracy | Resolution | Input impedance | 
|---|---|---|---|---|
| DCV | 400m/4/40/400/500V | ±(0.7%+3) | 0.1mV | 10M~100MΩ | 
| ACV | 4/40/400/500V | ±(2.3%+5) | 0.001V | 10M~11MΩ | 
| Resistance | 400/4k/40k/400k/4M/40MΩ | ±(2.0%+5) | 0.1Ω | |
| Capacitance | 5n/50n/500n/5μ/50μ/200μF | ±(5.0%+10) | 0.001nF | |
| Frequency | 9.999/99.99/999.9/9.999k/60.00kHz | ±(0.7%+5) | 0.001Hz | |
| Duty cycle | 0.1~99% | |||
| Continuity | Buzzer sounds at less than 10Ω~120Ω Open voltage:Approx.0.4V | |||
| Diode test | Open voltage:approx.1.5V | |||
| Display | numeral display 4000 | 
| Sampling rate | 3 times/sec. | 
| Bandwidth | 40~400Hz | 
| Bettry | Coin type lithium battery CR2032(3V)x1 | 
| Bettery life | Approx.150h at DCV | 
| Size/Mass | H108×W56×D11.5mm/Approx.50g | 
| Test lead length/Pin tip | Length: approx.0.5m/18mm | 
| Safety | IEC61010 CAT.ⅡDC/AC500V | 
	
															
															
															
															

		
		
		
		