{"id":24168,"date":"2023-01-20T11:22:56","date_gmt":"2023-01-20T03:22:56","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24168"},"modified":"2023-01-20T11:23:12","modified_gmt":"2023-01-20T03:23:12","slug":"fluke%e4%ba%a4%e7%9b%b4%e6%b5%81%e9%89%97%e8%a1%a8376","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/fluke%e4%ba%a4%e7%9b%b4%e6%b5%81%e9%89%97%e8%a1%a8376\/","title":{"rendered":"FLUKE\u4ea4\u76f4\u6d41\u9257\u8868376"},"content":{"rendered":"<h2><a href=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\"><img decoding=\"async\" class=\"alignnone wp-image-3127\" src=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\" alt=\"\" width=\"162\" height=\"52\" \/><\/a><\/h2>\n<h2><strong>Specifications<\/strong><\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<div class=\"clickability\">\n<table style=\"height: 3161px\" width=\"835\">\n<tbody>\n<tr>\n<td colspan=\"5\">Electrical Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC Current via Jaw<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">600.0 A<br \/>\n999.9 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">2% \u00b1 5 digits (10-100 Hz)<br \/>\n2.5% \u00b1 5 digits (100-500 Hz)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Crest Factor (50\/60 Hz)<\/td>\n<td colspan=\"2\">3 @ 500 A (375 and 376 only)<br \/>\n2.5 @ 600 A<br \/>\n1.42 @1000 A (376 only)<br \/>\nAdd 2% for C.F. &gt; 2<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">AC Current via Flexible Current Probe<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Range<\/td>\n<td colspan=\"2\">2500 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Resolution<\/td>\n<td><strong>374 and 375<\/strong><\/td>\n<td colspan=\"2\">0.1 A (\u2264 600 A)<br \/>\n1 A (\u2264 2500 A)<\/td>\n<\/tr>\n<tr>\n<td><strong>376<\/strong><\/td>\n<td colspan=\"2\">0.1 A (\u2264 999.9 A)<br \/>\n1 A (\u2264 2500 A)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">3% \u00b15 digits (5 \u2013 500 Hz)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Crest Factor (50\/60Hz)<\/td>\n<td colspan=\"2\">3.0 at 1100 A (375 and 376 only)<br \/>\n2.5 at 1400 A<br \/>\n1.42 at 2500 A<br \/>\nAdd 2% for C.F. &gt; 2<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"2\">Distance from Optimum<\/td>\n<td><strong>i2500-10 Flex<\/strong><\/td>\n<td><strong>i2500-18 Flex<\/strong><\/td>\n<td><strong>Error<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><img decoding=\"async\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\" alt=\"Flexible current probe\" \/><\/td>\n<td><strong>A<\/strong><\/td>\n<td>0.5 in (12.7 mm)<\/td>\n<td>1.4 in (35.6 mm)<\/td>\n<td>\u00b1 0.5%<\/td>\n<\/tr>\n<tr>\n<td><strong>B<\/strong><\/td>\n<td>0.8 in (20.3 mm)<\/td>\n<td>2.0 in (50.8 mm)<\/td>\n<td>\u00b1 1.0%<\/td>\n<\/tr>\n<tr>\n<td><strong>C<\/strong><\/td>\n<td>1.4 in (35.6 mm)<\/td>\n<td>2.5 in (63.5 mm)<\/td>\n<td>\u00b1 2.0%<\/td>\n<\/tr>\n<tr>\n<td class=\"nobold\" colspan=\"5\">Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">DC Current<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">600.0 A<br \/>\n999.9 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">2% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">AC Voltage<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">600.0 V<br \/>\n1000 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Resolution<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">0.1 V<br \/>\n0.1 V (\u2264 600.0 V)<br \/>\n1 V (\u2264 1000 V)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">1.5% \u00b1 5 digits (20 \u2013 500 Hz)<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">DC Voltage<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">600.0 V<br \/>\n1000 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Resolution<\/td>\n<td><strong>374 and 375<br \/>\n376<\/strong><\/td>\n<td colspan=\"2\">0.1 V<br \/>\n0.1 V (\u2264 600.0 V)<br \/>\n1 V (\u2264 1000 V)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">1% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">mV dc<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>375 and 376<\/strong><\/td>\n<td colspan=\"2\">500.0 mV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 mV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">1% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Frequency via Jaw<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>375 and 376<\/strong><\/td>\n<td colspan=\"2\">5.0 &#8211; 500.0 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">0.5% \u00b1 5 digits<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\">Trigger Level<\/td>\n<td colspan=\"2\">5 \u2013 10 Hz, \u226510 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">10 \u2013 100 Hz, \u22655 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">100 \u2013 500 Hz, \u226510 A<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Frequency via Flexible Current Probe<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>375 and 376<\/strong><\/td>\n<td colspan=\"2\">5.0 &#8211; 500.0 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">0.5% \u00b1 5 digits<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\">Trigger Level<\/td>\n<td colspan=\"2\">5 \u2013 20 Hz, \u2265 25 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">20 \u2013 100 Hz, \u2265 20 A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">100 \u2013 500 Hz, \u2265 25 A<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Resistance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Range<\/td>\n<td><strong>374<br \/>\n375 and 376<\/strong><\/td>\n<td colspan=\"2\">6000 \u03a9<br \/>\n60 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Resolution<\/td>\n<td><strong>374<\/strong><\/td>\n<td colspan=\"2\">0.1 \u03a9 (\u2264 600 \u03a9)<br \/>\n1 \u03a9 (\u2264 6000 \u03a9)<\/td>\n<\/tr>\n<tr>\n<td><strong>375 and 376<\/strong><\/td>\n<td colspan=\"2\">0.1 \u03a9 (\u2264 600 \u03a9)<br \/>\n1 \u03a9 (\u2264 6000 \u03a9)<br \/>\n10 \u03a9 (\u2264 60 k\u03a9)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">1% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Capacitance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Range<\/td>\n<td colspan=\"2\">1000 \u03bcF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Resolution<\/td>\n<td colspan=\"2\">0.1 \u03bcF (\u2264 100 \u03bcF)<br \/>\n1 \u03bc F (\u2264 1000 \u03bcF)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Accuracy<\/td>\n<td colspan=\"2\">1% \u00b1 4 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Mechanical Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Size (L x W x H)<\/td>\n<td colspan=\"2\">246 mm x 83 m x 43 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Weight<\/td>\n<td colspan=\"2\">388 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Jaw Opening<\/td>\n<td colspan=\"2\">34 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Flexible Current Probe Diameter<\/td>\n<td colspan=\"2\">7.5 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Flexible Current Probe Cable Length<br \/>\n(head to electronics connector)<\/td>\n<td colspan=\"2\">1.8 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Environmental Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Operating Temperature<\/td>\n<td colspan=\"2\">10\u00b0C \u2013 +50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Storage Temp<\/td>\n<td colspan=\"2\">-40\u00b0C \u2013 +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Operating Humidity<\/td>\n<td colspan=\"2\">Non condensing (&lt; 10 \u2013\u00b0C)<br \/>\n\u2264 90% RH (at 10\u00b0C \u2013 30\u00b0C)<br \/>\n\u2264 75% RH (at 30\u00b0C \u2013 40\u00b0C)<br \/>\n\u2264 45% RH (at 40\u00b0C \u2013 50\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Operating Altitude<\/td>\n<td colspan=\"2\">3000 meters<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Storage Altitude<\/td>\n<td colspan=\"2\">12,000 meters<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">EMC<\/td>\n<td colspan=\"2\">EN 61326-1:2006<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Temperature Coefficients<\/td>\n<td colspan=\"2\">Add 0.1 x specified accuracy for each<br \/>\ndegree C above 28\u00b0C or below 18\u00b0C<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Safety Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Safety Compliance<\/td>\n<td colspan=\"2\">CAN\/CSA-C22.2 No. 61010-1-04<br \/>\nANSI\/UL 61010-1:2004<br \/>\nANSI\/ISA-61010-1 (82.02.01):2004<br \/>\nEN\/IEC 61010-1:2001 to<br \/>\n1000V Measurement Category (CAT) III<br \/>\n600V Measurement Category (CAT) IV<br \/>\nPollution Degree 2<br \/>\nEN\/IEC 61010-2-032:2002<br \/>\nEN\/IEC 61010-031:2002+A1:2008<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Agency Approvals<\/td>\n<td class=\"certifications\" colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Batteries<\/td>\n<td colspan=\"2\">2 AA, NEDA 15A, IEC LR6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li>iFlex<sup>\u00ae<\/sup>\u00a0Flexible Current Probe expands the measurement range to 2500 A AC<\/li>\n<li>CAT IV 600 V, CAT III 1000 V<\/li>\n<li>True RMS AC voltage and current for accurate measurements on non-linear signals<\/li>\n<li>Min, max, average and Inrush recording to capture variations automatically<\/li>\n<li>Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings<\/li>\n<li>Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it<\/li>\n<li>Ergonomic design fits in your hand and can be used while wearing protective equipment<\/li>\n<li>Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement<\/li>\n<li>Three-year warranty<\/li>\n<li>Soft Carrying Case<\/li>\n<\/ul>","protected":false},"featured_media":18461,"template":"","meta":[],"product_cat":[205],"product_tag":[113],"class_list":{"0":"post-24168","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-205","7":"product_tag-fluke","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24168","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24168\/revisions"}],"predecessor-version":[{"id":24196,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24168\/revisions\/24196"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/18461"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24168"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24168"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}