{"id":24171,"date":"2023-01-20T11:22:56","date_gmt":"2023-01-20T03:22:56","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24171"},"modified":"2023-01-20T11:23:14","modified_gmt":"2023-01-20T03:23:14","slug":"fluke%e6%95%b8%e5%ad%97%e8%90%ac%e7%94%a8%e8%a1%a8107","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/fluke%e6%95%b8%e5%ad%97%e8%90%ac%e7%94%a8%e8%a1%a8107\/","title":{"rendered":"FLUKE\u6578\u5b57\u842c\u7528\u8868107"},"content":{"rendered":"<h2><a href=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\"><img decoding=\"async\" class=\"alignnone wp-image-3127\" src=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\" alt=\"\" width=\"162\" height=\"52\" \/><\/a><\/h2>\n<h2><strong>Specifications<\/strong><\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<div class=\"clickability\">\n<p>Accuracy is available for one year after calibration, operating from 18 \u00b0C to 28 \u00b0C and relative humidity from 0% to 75%. The format of the accuracy specification is: \u00b1 ([% of reading] + [least significant digit])<\/p>\n<table style=\"height: 1797px\" width=\"835\">\n<tbody>\n<tr class=\"head\">\n<td colspan=\"5\">Precision specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\"><strong>AC voltage<br \/>\n(40 Hz to 500 Hz)<sup>1<\/sup><\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td>6.000 V<br \/>\n60.00 V<br \/>\n600.0 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<\/td>\n<td>1.0 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>DC voltage<\/strong><\/td>\n<td>6.000 V<br \/>\n60.00 V<br \/>\n600.0 V<\/td>\n<td>0.001 V<br \/>\n0.01 V<br \/>\n0.1 V<\/td>\n<td>0.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Exchange millivolts<\/strong><\/td>\n<td>600.0 mV<\/td>\n<td>0.1 mV<\/td>\n<td>3.0 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Diode test<sup>2<\/sup><\/strong><\/td>\n<td>2.000 V<\/td>\n<td>0.001 V<\/td>\n<td>10 %<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Resistance<br \/>\n(ohm)<\/strong><\/td>\n<td>400.0 \u03a9<br \/>\n4.000 k\u03a9<br \/>\n40.00 k\u03a9<br \/>\n400.0 k\u03a9<br \/>\n4.000 M\u03a9<br \/>\n40.00 M\u03a9<\/td>\n<td>0.1 \u03a9<br \/>\n0.001 k\u03a9<br \/>\n0.01 k\u03a9<br \/>\n0.1 k\u03a9<br \/>\n0.001 M\u03a9<br \/>\n0.01 M\u03a9<\/td>\n<td>0.5 % + 3<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n0.5 % + 2<br \/>\n1.5% + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Capacitor<sup>3<\/sup><\/strong><\/td>\n<td>50.00 nF<br \/>\n500.0 nF<br \/>\n5.000 \u03bcF<br \/>\n50.00 \u03bcF<br \/>\n500.0 \u03bcF<br \/>\n1000 \u03bcF<\/td>\n<td>0.01 nF<br \/>\n0.1 nF<br \/>\n0.001 \u03bcF<br \/>\n0.01 \u03bcF<br \/>\n0.1 \u03bcF<br \/>\n1 \u03bcF<\/td>\n<td>2 % + 5<br \/>\n2 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<br \/>\n5 % + 5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Frequency<sup>4<\/sup>\u00a0Hz<br \/>\n(10 Hz \u2013 100 kHz)<\/strong><\/td>\n<td>50.00 Hz<br \/>\n500.0 Hz<br \/>\n5.000 kHz<br \/>\n50.00 kHz<br \/>\n100.0 kHz<\/td>\n<td>0.01 Hz<br \/>\n0.1 Hz<br \/>\n0.001 kHz<br \/>\n0.01 kHz<br \/>\n0.1 kHz<\/td>\n<td>0.1 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Duty cycle<sup>4<\/sup><\/strong><\/td>\n<td>1 % to 99 %<\/td>\n<td>0.10 %<\/td>\n<td>1 % typical case<sup>5<\/sup><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>AC current<br \/>\n(40 Hz &#8211; 200 Hz)<\/strong><\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>DC<\/strong><\/td>\n<td>4.000 A<br \/>\n10.00 A<\/td>\n<td>0.001 A<br \/>\n0.01 A<\/td>\n<td>1.5 % + 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<ol>\n<li>All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.<\/li>\n<li>Typically, the open circuit test voltage is 2.0 V and the short circuit current is &lt; 0.6 mA.<\/li>\n<li>The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).<\/li>\n<li>All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.<\/li>\n<li>Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"20%\"><strong>Features<\/strong><\/td>\n<td width=\"20%\"><strong>Overload protection<\/strong><\/td>\n<td width=\"20%\"><strong>Input impedance (nominal value)<\/strong><\/td>\n<td width=\"20%\"><strong>Common mode rejection ratio<\/strong><\/td>\n<td width=\"20%\"><strong>Normal mode rejection ratio<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>AC voltage<\/strong><\/td>\n<td>600 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF\u00a0<sup>2<\/sup><\/td>\n<td>&gt;60 dB at 50 Hz or 60 Hz at DC current<\/td>\n<td>\u2212<\/td>\n<\/tr>\n<tr>\n<td><strong>Exchange millivolts<\/strong><\/td>\n<td>600 mV<\/td>\n<td>&gt;1M, &lt;100 pF<\/td>\n<td>&gt;80 dB at 50 Hz or 60 Hz<\/td>\n<td>\u2212<\/td>\n<\/tr>\n<tr>\n<td><strong>DC voltage<\/strong><\/td>\n<td>600 V\u00a0<sup>1<\/sup><\/td>\n<td>&gt;10 M\u03a9 &lt;100 pF<\/td>\n<td>&gt;100 dB at 50 Hz or 60 Hz at DC current<\/td>\n<td>&gt;60 dB at 50 Hz or 60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<ol>\n<li>Up to 6 x 105 V Hz<\/li>\n<li>For medium voltage (alternating current), the input impedance is approximately 1 M\u03a9.<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">General technical indicators<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>The highest voltage applied to any terminal and ground<\/strong><\/td>\n<td colspan=\"3\">600 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Display (LCD)<\/strong><\/td>\n<td colspan=\"3\">6000 counts, updated three times per second<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Type of battery<\/strong><\/td>\n<td colspan=\"3\">Two AAA batteries (NEDA 24A, IEC LR03)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Battery life<\/strong><\/td>\n<td colspan=\"3\">At least 200 hours<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Temperature<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Operating temperature<\/strong><\/td>\n<td colspan=\"3\">0 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Storage temperature<\/strong><\/td>\n<td colspan=\"3\">-30 \u00b0C to 60 \u00b0C<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Relative humidity<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Working humidity<\/strong><\/td>\n<td colspan=\"3\">No condensation below 10 \u00b0C<br \/>\n\u2264 90 % at 10 \u00b0C to 30 \u00b0C; \u2264 75 % at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Working humidity, 40 M\u03a9 range<\/strong><\/td>\n<td colspan=\"3\">\u2264 80 % at 10 \u00b0C to 30 \u00b0C; \u2264 70 % at 30 \u00b0C to 40 \u00b0C<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"5\">Altitude<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Working elevation<\/strong><\/td>\n<td colspan=\"3\">2000 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Storage altitude<\/strong><\/td>\n<td colspan=\"3\">12,000 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Temperature coefficient<\/strong><\/td>\n<td colspan=\"3\">0.1 X (specified accuracy) \/ \u00b0C (&lt;18 \u00b0C or &gt;28 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Current input fuse protection<\/strong><\/td>\n<td colspan=\"3\">11A, 1000V fast-melting type, must use Fluke designated parts<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Volume (height x width x length)<\/strong><\/td>\n<td colspan=\"3\">142 mm x 69 mm x 28 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Weight<\/strong><\/td>\n<td colspan=\"3\">200 g<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Protection level<\/strong><\/td>\n<td colspan=\"3\">IEC 60529: IP 40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Safety<\/strong><\/td>\n<td colspan=\"3\">IEC 61010-1: 600 V CAT III, pollution degree 2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Electromagnetic environment<\/strong><\/td>\n<td colspan=\"3\">IEC 61326-1: Portable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Electromagnetic compatibility<\/strong><\/td>\n<td colspan=\"3\">Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)<sup>1<\/sup><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><sup>1<\/sup>\u00a0This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li>CAT III 600 V safety rating<\/li>\n<li>Current and voltage measurements<\/li>\n<li>Measures resistance and continuity to check for broken wires<\/li>\n<li>Data hold and backlit display to keep you working safe and fast<\/li>\n<\/ul>","protected":false},"featured_media":18488,"template":"","meta":[],"product_cat":[205],"product_tag":[113],"class_list":{"0":"post-24171","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-205","7":"product_tag-fluke","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24171\/revisions"}],"predecessor-version":[{"id":24199,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24171\/revisions\/24199"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/18488"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24171"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24171"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}