{"id":24176,"date":"2023-01-20T11:22:57","date_gmt":"2023-01-20T03:22:57","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24176"},"modified":"2023-01-20T11:23:22","modified_gmt":"2023-01-20T03:23:22","slug":"fluke-f317%e9%89%97%e5%bd%a2%e9%9b%bb%e6%b5%81%e9%8c%b6","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/fluke-f317%e9%89%97%e5%bd%a2%e9%9b%bb%e6%b5%81%e9%8c%b6\/","title":{"rendered":"FLUKE F317\u9257\u5f62\u96fb\u6d41\u9336"},"content":{"rendered":"<h2><a href=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\"><img decoding=\"async\" class=\"alignnone wp-image-3127\" src=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\" alt=\"\" width=\"162\" height=\"52\" \/><\/a><\/h2>\n<h2><strong>Specifications<\/strong><\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<table style=\"height: 424px\" width=\"640\">\n<tbody>\n<tr class=\"head\">\n<td colspan=\"2\">General specifications<\/td>\n<\/tr>\n<tr>\n<td>Digital display<\/td>\n<td>6000 count resolution<\/td>\n<\/tr>\n<tr>\n<td>Low battery Indication<\/td>\n<td>Displays a signal when the batteries are below their required voltage<\/td>\n<\/tr>\n<tr>\n<td>Power source<\/td>\n<td>Three AAA IEC LR03 batteries<\/td>\n<\/tr>\n<tr>\n<td>Clamp opening size<\/td>\n<td>1.45 in (37 mm)<\/td>\n<\/tr>\n<tr>\n<td>Jaw diameter<\/td>\n<td>1.45 in (37 mm)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Dimensions (L x W x H)<\/td>\n<td>6.39 x 2.29 x 1.20 in<\/td>\n<\/tr>\n<tr>\n<td>(162.4 x 58.25 x 30.5 mm)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approximately 13.5 oz (384 g) (batteries included)<\/td>\n<\/tr>\n<tr>\n<td>Auto range<\/td>\n<td>Available in Ohms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Safety<\/td>\n<td>CE<\/td>\n<\/tr>\n<tr>\n<td>EN\/IEC 61010-1 and IEC 61010-2-032<\/td>\n<\/tr>\n<tr>\n<td>Measurement Category: 600V CAT III<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr class=\"head\">\n<td colspan=\"3\">317 Electrical specifications<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Current AC<\/td>\n<td>Range<\/td>\n<td>40.00 A, 600.0 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 A, 0.1 A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Accuracy<\/td>\n<td>1.6% \u00b16 digit (50-60 Hz) {40 A}<\/td>\n<\/tr>\n<tr>\n<td>2.5% \u00b18 digit (60-500 Hz) {40 A}<\/td>\n<\/tr>\n<tr>\n<td>1.5% \u00b15 digit (50-60 Hz) {600 A}<\/td>\n<\/tr>\n<tr>\n<td>2.5% \u00b15 digit (60-500 Hz) {600 A}<\/td>\n<\/tr>\n<tr>\n<td>Crest Factor add 2% into spec for CF &gt; 2<\/td>\n<td>3.0 Max @ 500 A, 2.5 Max @ 600 A<\/td>\n<\/tr>\n<tr>\n<td>AC response<\/td>\n<td>rms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Current DC<\/td>\n<td>Range<\/td>\n<td>40.00 A, 600.0 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 A, 0.1 A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Accuracy<\/td>\n<td>1.6% \u00b16 digit (40 A)<\/td>\n<\/tr>\n<tr>\n<td>1.5% \u00b15 digit (600 A)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Voltage AC<\/td>\n<td>Range<\/td>\n<td>600.0 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1.5% \u00b15 digit (20-500Hz)<\/td>\n<\/tr>\n<tr>\n<td>AC response<\/td>\n<td>rms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Voltage DC<\/td>\n<td>Range<\/td>\n<td>600.0 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% \u00b14 digit<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Resistance<\/td>\n<td>Range<\/td>\n<td>400.0 \u03a9, 4000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 \u03a9, 1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% \u00b15 digit<\/td>\n<\/tr>\n<tr>\n<td>Continuity<\/td>\n<td colspan=\"2\">\u2264 30 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Inrush<\/td>\n<td>Integration time<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Frequency<\/td>\n<td>Range<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Trigger Level<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 967px\" width=\"639\">\n<tbody>\n<tr class=\"head\">\n<td colspan=\"3\">319 Electrical specifications<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Current AC<\/td>\n<td>Range<\/td>\n<td>40.00 A, 600.0 A, 1000 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 A, 0.1 A, 1 A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Accuracy<\/td>\n<td>1.6% \u00b16 digit (50-60 Hz) {40 A}<\/td>\n<\/tr>\n<tr>\n<td>2.5% \u00b18 digit (60-500 Hz) {40 A}<\/td>\n<\/tr>\n<tr>\n<td>1.5% \u00b15 digit (50-60 Hz) {600\/1000 A}<\/td>\n<\/tr>\n<tr>\n<td>2.5% \u00b15 digit (60-500 Hz) {600\/1000 A}<\/td>\n<\/tr>\n<tr>\n<td>Crest Factor add 2% into spec for CF &gt; 2<\/td>\n<td>3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A<\/td>\n<\/tr>\n<tr>\n<td>AC response<\/td>\n<td>rms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Current DC<\/td>\n<td>Range<\/td>\n<td>40.00 A, 600.0 A, 1000 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 A, 0.1 A, 1 A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Accuracy<\/td>\n<td>1.6% \u00b16 digit (40 A)<\/td>\n<\/tr>\n<tr>\n<td>1.5% \u00b15 digit (600\/1000 A)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Voltage AC<\/td>\n<td>Range<\/td>\n<td>600.0 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1.5% \u00b15 digit (20-500Hz)<\/td>\n<\/tr>\n<tr>\n<td>AC response<\/td>\n<td>rms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Voltage DC<\/td>\n<td>Range<\/td>\n<td>600.0 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% \u00b14 digit<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Resistance<\/td>\n<td rowspan=\"2\">Range<\/td>\n<td>400.0 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>4000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Resolution<\/td>\n<td>0.1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% \u00b15 digit<\/td>\n<\/tr>\n<tr>\n<td>Continuity<\/td>\n<td colspan=\"2\">\u2264 30 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Inrush<\/td>\n<td>Integration time<\/td>\n<td>100 ms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Frequency<\/td>\n<td>Range<\/td>\n<td>5.0 &#8211; 500.0 Hz<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>0.5% \u00b15 digit<\/td>\n<\/tr>\n<tr>\n<td>Trigger Level<\/td>\n<td>10 &#8211; 100 Hz \u2265 5 A, 5 &#8211; 10 Hz, 100 &#8211; 500 Hz \u2265 10 A<\/td>\n<\/tr>\n<tr>\n<td class=\"small-font\" colspan=\"3\">The accuracy specifications aply at 73 \u00b0F \u00b141 \u00b0F (23 \u00b0C \u00b15 \u00b0C)<br \/>\nBelow 64 \u00b0F and above 82 \u00b0F (18 \u00b0C and above 28 \u00b0C) accuracy degrades at (0.1) times specification per \u00b0C.<br \/>\nTrue rms for ac V and ac A accuracy is specified from 5% to 100% of range.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 510px\" width=\"641\">\n<tbody>\n<tr class=\"head\">\n<td colspan=\"2\">Environmental specifications<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>14\u00b0F to 122\u00b0F (-10 \u00b0C to 50 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>-40 \u00b0F to 140 \u00b0F (-40 \u00b0C to 60 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Operating humidity<\/td>\n<td>Non-condensing (&lt; 50 \u00b0F) (&lt; 10 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>90% RH (50 \u00b0F to 86 \u00b0F) (10 \u00b0C to 30 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>75% RH (86 \u00b0F to 104 \u00b0F) (30 \u00b0C to 40 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>45% RH (104 \u00b0F to 122 \u00b0F) (40 \u00b0C to 50 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>(Without condensation)<\/td>\n<\/tr>\n<tr>\n<td>Operating altitude<\/td>\n<td>1 mile (2000 meters) above mean sea level<\/td>\n<\/tr>\n<tr>\n<td>Storage altitude<\/td>\n<td>7 miles (12,000 meters) above mean sea level<\/td>\n<\/tr>\n<tr>\n<td>IP Rating<\/td>\n<td>IP40<\/td>\n<\/tr>\n<tr>\n<td>Vibration requirements<\/td>\n<td>Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis<\/td>\n<\/tr>\n<tr>\n<td>Drop test requirements<\/td>\n<td>3 ft (1 m) drop test, six sides, oak floor<\/td>\n<\/tr>\n<tr>\n<td>EMI, RFI, EMC<\/td>\n<td>Instrument unspecified for use in EMC field \u2265 0.1 V\/m<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Temperature coefficients<\/td>\n<td>0.1x (specified accuracy)\/ \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>(&lt;64 \u00b0F or &gt; 82\u00b0 F)<\/td>\n<\/tr>\n<tr>\n<td>(&lt;18 \u00b0C or &gt; 28 \u00b0C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Unique 40A high-precision low current measurement&#8211;0.01A high-resolution, 1.6% high-precision measurement<\/li>\n<li>The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces<\/li>\n<li>The large backlight display facilitates readings in dark environments<\/li>\n<li>Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)<\/li>\n<li>Current frequency measurement<\/li>\n<li>Precision down to 0.01A and 0.1V<\/li>\n<li>1000A\/600A AC\/DC current measurement (319\/317)<\/li>\n<li>600V AC\/DC voltage measurement<\/li>\n<li>4000\u03a9 resistance measurement<\/li>\n<li>Continuity beeper<\/li>\n<li>Auto off function enhances battery life, meaning the instrument can work when you need it screen store \u2018hold\u2019 function for capturing a measurement result on the screen<\/li>\n<li>One year warranty<\/li>\n<\/ul>","protected":false},"featured_media":18521,"template":"","meta":[],"product_cat":[205],"product_tag":[113],"class_list":{"0":"post-24176","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-205","7":"product_tag-fluke","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24176\/revisions"}],"predecessor-version":[{"id":24231,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24176\/revisions\/24231"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/18521"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24176"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}