{"id":24205,"date":"2023-01-20T11:23:17","date_gmt":"2023-01-20T03:23:17","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24205"},"modified":"2023-01-20T11:23:26","modified_gmt":"2023-01-20T03:23:26","slug":"fluke-1663-%e5%a4%9a%e5%8a%9f%e8%83%bd%e9%9b%bb%e6%b0%a3%e6%b8%ac%e8%a9%a6%e5%84%80","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/fluke-1663-%e5%a4%9a%e5%8a%9f%e8%83%bd%e9%9b%bb%e6%b0%a3%e6%b8%ac%e8%a9%a6%e5%84%80\/","title":{"rendered":"FLUKE 1663 \u591a\u529f\u80fd\u96fb\u6c23\u6e2c\u8a66\u5100"},"content":{"rendered":"<h2><a href=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\"><img decoding=\"async\" class=\"alignnone wp-image-3127\" src=\"http:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/fluke-corporation-logo-vector.bmp\" alt=\"\" width=\"162\" height=\"52\" \/><\/a><\/h2>\n<h2><strong>Specifications<\/strong><\/h2>\n<div id=\"fluke-product-display-specs\">\n<div id=\"product-specs\">\n<div id=\"specification_content\">\n<div class=\"clickability\">\n<table style=\"height: 2523px\" width=\"636\">\n<tbody>\n<tr>\n<td colspan=\"3\">AC voltage measurement<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"2\">500 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">0.1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy 45 Hz \u2013 66 Hz<\/td>\n<td colspan=\"2\">0.8% + 3<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td colspan=\"2\">360 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Overload protection<\/td>\n<td colspan=\"2\">660 V rms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Continuity testing (RLO)<\/td>\n<\/tr>\n<tr>\n<td>Range (autoranging)<\/td>\n<td colspan=\"2\">20 \u03a9 \/ 200 \u03a9 \/ 2000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">0.01 \u03a9 \/ 0.1 \u03a9 \/ 1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Open Circuit Voltage<\/td>\n<td colspan=\"2\">&gt;4 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Insulation resistance measurement (RISO)<\/td>\n<\/tr>\n<tr>\n<td>Test voltages<\/td>\n<td colspan=\"2\">50-100-250-500-1000 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy of tTest voltage (at rated test current)<\/td>\n<td colspan=\"2\">+10%, -0%<\/td>\n<\/tr>\n<tr>\n<td>Test voltage<\/td>\n<td colspan=\"2\">50 V<br \/>\n100 V<br \/>\n250 V<br \/>\n500 V<br \/>\n1000 V<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance range<\/td>\n<td colspan=\"2\">20 M\u03a9 \/50 M\u03a9<br \/>\n20 M\u03a9 \/ 100 M\u03a9<br \/>\n20 M\u03a9 \/ 200 M\u03a9<br \/>\n20 M\u03a9 \/ 200 M\u03a9 \/ 500 M\u03a9<br \/>\n20 M\u03a9 \/ 200 M\u03a9 \/ 1000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">0.01 M\u03a9 \/ 0.1 M\u03a9<br \/>\n0.01 M\u03a9 \/ 0.1 M\u03a9<br \/>\n0.01 M\u03a9 \/ 0.1 M\u03a9<br \/>\n0.01 M\u03a9 \/ 0.1 M\u03a9 \/ 1 M\u03a9<br \/>\n0.01 M\u03a9 \/ 0.1 M\u03a9 \/ 1 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Test current<\/td>\n<td colspan=\"2\">1 mA @ 50 k\u03a9<br \/>\n1 mA @ 100 k\u03a9<br \/>\n1 mA @ 250 k\u03a9<br \/>\n1 mA @ 500 k\u03a9<br \/>\n1 mA @ 1 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Loop and line impedance (ZI)<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"2\">10 \u03a9 \/ 0.001 \u03a9 \/ High current m\u03a9 mode<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">0.01 \u03a9 \/ 0.1 \u03a9 \/ 1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Prospective earth fault current, PSC test<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"2\">1000 A \/ 10 kA (50 kA)<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">1 A \/ 0.1 kA<\/td>\n<\/tr>\n<tr>\n<td>Computation<\/td>\n<td colspan=\"2\">Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">RCD testing, RCD types tested<\/td>\n<\/tr>\n<tr>\n<td>RCD Type<\/td>\n<td colspan=\"2\">AC\u00b9<br \/>\nG\u00b2,S\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Model 1663<\/td>\n<td colspan=\"2\">A<sup>4<\/sup>, AC\u00b9, G\u00b2,S\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Notes<\/td>\n<td colspan=\"2\">\u00b9Responds to AC<br \/>\n\u00b2General, no delay<br \/>\n\u00b3Time delay<br \/>\n<sup>4<\/sup>Responds to pulsed signal<br \/>\n<sup>5<\/sup>Responds to smooth DC signal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Tripping speed test (\u0394T)<\/td>\n<\/tr>\n<tr>\n<td>Current settings\u00b9<\/td>\n<td colspan=\"2\">10-30-100-300-500-1000 mA \u2013 VAR<br \/>\n10-30-100 mA<\/td>\n<\/tr>\n<tr>\n<td>Multiplier<\/td>\n<td colspan=\"2\">x \u00bd, x 1<br \/>\nx 5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Measurement range<\/td>\n<td>RCD Type G<\/td>\n<td>310 ms<br \/>\n50 ms<\/td>\n<\/tr>\n<tr>\n<td>RCD Type S<\/td>\n<td>510 ms<br \/>\n160 ms<\/td>\n<\/tr>\n<tr>\n<td>Notes<\/td>\n<td colspan=\"2\">\u00b91000 mA type AC only<br \/>\n700 mA maximum type A in VAR mode<br \/>\nVAR mode not available for type B.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">RCD\/FI-Tripping Current Measurement\/Ramp Test (I\u0394N)<\/td>\n<\/tr>\n<tr>\n<td>Current range<\/td>\n<td colspan=\"2\">30% to 110% of RCD rated current\u00b9<\/td>\n<\/tr>\n<tr>\n<td>Step size<\/td>\n<td colspan=\"2\">10% of I\u0394N\u00b2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Dwell time<\/td>\n<td>Type G<\/td>\n<td>300 ms\/step<\/td>\n<\/tr>\n<tr>\n<td>Type S<\/td>\n<td>500 ms\/step<\/td>\n<\/tr>\n<tr>\n<td>Measurement accuracy<\/td>\n<td colspan=\"2\">\u00b15%<\/td>\n<\/tr>\n<tr>\n<td>Specified trip current ranges (EN 61008-1)<\/td>\n<td colspan=\"2\">50% to 100% for Type AC<br \/>\n35% to 140% for Type A (&gt;10 mA)<br \/>\n35% to 200% for Type A (\u226410 mA)<br \/>\n50% to 200% for Type B<br \/>\n\u00b25% for Type B<\/td>\n<\/tr>\n<tr>\n<td>Notes<\/td>\n<td colspan=\"2\">\u00b930% to 150% for Type A I\u0394N &gt; 10 mA<br \/>\n30% to 210% for Type A I\u0394N = 10 mA<br \/>\n20% to 210% for Type B<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Earth Resistance Test (RE)<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"2\">200 \u03a9 \/ 2000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"2\">0.1 \u03a9 \/ 1\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td colspan=\"2\">128 Hz<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage<\/td>\n<td colspan=\"2\">25 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Phase Sequence Indication<\/td>\n<\/tr>\n<tr>\n<td>Icon<\/td>\n<td colspan=\"2\"><img decoding=\"async\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\" alt=\"icon phase sequence indicator \" align=\"top\" \/>\u00a0Phase Sequence indicator is active.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">General Specifications<\/td>\n<\/tr>\n<tr>\n<td>Size (L x W x H)<\/td>\n<td colspan=\"2\">10 x 25 x 12.5 cm<\/td>\n<\/tr>\n<tr>\n<td>Weight (incl. batteries)<\/td>\n<td colspan=\"2\">1.3 Kg<\/td>\n<\/tr>\n<tr>\n<td>Battery size, quantity<\/td>\n<td colspan=\"2\">Type AA, 6 ea.<\/td>\n<\/tr>\n<tr>\n<td>Sealing<\/td>\n<td colspan=\"2\">IP-40<\/td>\n<\/tr>\n<tr>\n<td>Safety<\/td>\n<td colspan=\"2\">Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI\/ISA \u2013s82.02.01 2000 and CAN\/CSA c22.2 No. 1010 2nd edition<\/td>\n<\/tr>\n<tr>\n<td>Overvoltage<\/td>\n<td colspan=\"2\">CAT III \/ 500V; CAT IV 300V<\/td>\n<\/tr>\n<tr>\n<td>Performance<\/td>\n<td colspan=\"2\">EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Full featured tester for installation professionals<\/li>\n<li>Tests to all local regulations and provides test results for complete documentation<\/li>\n<li>Tests continuity at L-N, N-PE inputs<\/li>\n<li>Tests smooth dc sensitive RCDs (Type B)<\/li>\n<li>Tests earth resistance, voltage, and frequency<\/li>\n<li>Offers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V<\/li>\n<\/ul>","protected":false},"featured_media":18541,"template":"","meta":[],"product_cat":[205],"product_tag":[113],"class_list":{"0":"post-24205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-205","7":"product_tag-fluke","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24205\/revisions"}],"predecessor-version":[{"id":24235,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24205\/revisions\/24235"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/18541"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24205"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}