{"id":24311,"date":"2023-01-20T11:24:06","date_gmt":"2023-01-20T03:24:06","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24311"},"modified":"2023-01-20T11:24:22","modified_gmt":"2023-01-20T03:24:22","slug":"uni-t%e5%a4%9a%e5%8a%9f%e8%83%bd%e9%9b%bb%e6%b0%a3%e6%b8%ac%e8%a9%a6%e8%ad%b0ut526","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/uni-t%e5%a4%9a%e5%8a%9f%e8%83%bd%e9%9b%bb%e6%b0%a3%e6%b8%ac%e8%a9%a6%e8%ad%b0ut526\/","title":{"rendered":"UNI-T\u591a\u529f\u80fd\u96fb\u6c23\u6e2c\u8a66\u8b70UT526"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone wp-image-5875\" src=\"https:\/\/www.scecl.com\/wp-content\/uploads\/2022\/06\/LOGO.jpg\" alt=\"\" width=\"166\" height=\"65\" \/><\/p>\n<h2><strong>Specifications<\/strong><\/h2>\n<table style=\"height: 1155px\" border=\"0\" width=\"579\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"8\" height=\"128\">Insulation resistance (\u03a9)<\/td>\n<td>Test voltages<\/td>\n<td>250V\/500V\/1000V<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">250V<\/td>\n<td>0.05M\u03a9~200M\u03a9<\/td>\n<td>\u00b1(5%+5)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">500V<\/td>\n<td>0.05M\u03a9~300M\u03a9<\/td>\n<td>\u00b1(5%+5)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">1000V<\/td>\n<td>0.05M\u03a9~500M\u03a9<\/td>\n<td>\u00b1(5%+5)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" height=\"48\">Load current<\/td>\n<td>250V (R=250k\u03a9) 1mA<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">500V (R=500k\u03a9) 1mA<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">1000V (R=1M\u03a9) 1mA<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Short circuit current<\/td>\n<td>&lt;2mA<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" height=\"80\">RCD<\/td>\n<td>Operating voltage (Freq.)<\/td>\n<td>220V (45Hz~65Hz)<\/td>\n<td>\u00b110%<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Test current<\/td>\n<td>10mA\/30mA\/100mA\/300mA<\/td>\n<td>0~20%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" height=\"48\">Trip time<\/td>\n<td>0ms~2000ms, 1\u0394n general (10mA)<\/td>\n<td rowspan=\"3\">\u00b1(5%+2)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">0ms~500ms, 1\u0394n general<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">0ms~300ms, 1\u0394n general (100mA, 300mA)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" height=\"48\">Low resistance continuity<\/td>\n<td>Range<\/td>\n<td>0\u03a9~2000\u03a9<\/td>\n<td>\u00b1(2%+5)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Test voltage<\/td>\n<td>Around 5V<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Test current<\/td>\n<td>&gt;200mA (R&lt;2\u03a9)<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" height=\"48\">Voltage measurement (V)<\/td>\n<td>DC voltage<\/td>\n<td>0~440V<\/td>\n<td rowspan=\"2\">\u00b1(5%+2)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">AC voltage<\/td>\n<td>0~440V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Frequency (For reference only)<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" height=\"16\"><strong>Features<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Display count<\/td>\n<td colspan=\"2\"><\/td>\n<td>10000<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Manual range<\/td>\n<td colspan=\"2\"><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Phase switch (RCD)<\/td>\n<td colspan=\"2\">0\u00b0and 180\u00b0<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Low battery indication<\/td>\n<td colspan=\"2\"><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Auto AC\/DC voltage identification<\/td>\n<td colspan=\"2\"><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Red warning lights<\/td>\n<td colspan=\"2\"><\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" height=\"16\"><strong>General Characterisitics<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Power<\/td>\n<td colspan=\"3\">1.5V battery (LR6) x 6<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Display<\/td>\n<td colspan=\"3\">71mm x 34mm<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Product color<\/td>\n<td colspan=\"3\">Red and grey<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Product net weight<\/td>\n<td colspan=\"3\">380g<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Product size<\/td>\n<td colspan=\"3\">160mm x 100mm x 71mm<\/td>\n<\/tr>\n<tr>\n<td height=\"19\">Standard accessories<\/td>\n<td colspan=\"3\">Batteries, carrying bag, gallus, test leads, alligator clips, test line<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Standard individual packing<\/td>\n<td colspan=\"3\">Gift box, English manual<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Standard quantity per carton<\/td>\n<td colspan=\"3\">10pcs<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Standard carton measurement<\/td>\n<td colspan=\"3\">445mm x 440mm x 180mm (0.063 CBM per standard carton)<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Standard carton gross weight<\/td>\n<td colspan=\"3\">12.8kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<ul>\n<li>UT526 is a multifunctional electrical installation tester.<\/li>\n<li>It can be used to test insulation resistance, RCD status, low resistance continuity, and voltage measurements.<\/li>\n<li>UT526 can be used to test power distribution system, lightning protection system and wiring systems to ensure safe operations.<\/li>\n<\/ul>","protected":false},"featured_media":18902,"template":"","meta":[],"product_cat":[205],"product_tag":[134],"class_list":{"0":"post-24311","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-205","7":"product_tag-uni-t","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24311\/revisions"}],"predecessor-version":[{"id":24341,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24311\/revisions\/24341"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/18902"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24311"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24311"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}