{"id":24510,"date":"2023-01-20T11:25:43","date_gmt":"2023-01-20T03:25:43","guid":{"rendered":"https:\/\/www.scecl.com\/?post_type=product&#038;p=24510"},"modified":"2023-01-20T11:26:09","modified_gmt":"2023-01-20T03:26:09","slug":"commscope-cs31cm-%e5%85%ad%e9%a1%9e%e9%9d%9e%e5%b1%8f%e8%94%bd%e7%b6%b2%e7%b7%9a-2","status":"publish","type":"product","link":"https:\/\/www.scecl.com\/en\/product\/commscope-cs31cm-%e5%85%ad%e9%a1%9e%e9%9d%9e%e5%b1%8f%e8%94%bd%e7%b6%b2%e7%b7%9a-2\/","title":{"rendered":"Commscope CS31CM \u516d\u985e\u975e\u5c4f\u853d\u7db2\u7dda"},"content":{"rendered":"<div id=\"specifications\" class=\"Product-specifications\">\n<div class=\"row\">\n<div class=\"col-md-12\">\n<h1 class=\"desktop-only\">1427254-6 | CS31CM BLU C6 4\/23 U\/UTP RIB 305M<\/h1>\n<h1 class=\"section-title\"><span style=\"color: #1aa7ec;\">Specifications<\/span><\/h1>\n<h2 class=\"heading-title\">Product Classification<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 81px;\" width=\"457\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Regional Availability<\/td>\n<td>Asia | Latin America<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Portfolio<\/td>\n<td>NETCONNECT\u00ae<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Product Type<\/td>\n<td>Twisted pair cable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">General Specifications<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 248px;\" width=\"862\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Product Number<\/td>\n<td>CS31CM<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">ANSI\/TIA Category<\/td>\n<td>6<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Cable Component Type<\/td>\n<td>Horizontal<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Cable Type<\/td>\n<td>U\/UTP (unshielded)<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Conductor Type, singles<\/td>\n<td>Solid<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Conductors, quantity<\/td>\n<td>8<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Jacket Color<\/td>\n<td>Blue<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Pairs, quantity<\/td>\n<td>4<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Transmission Standards<\/td>\n<td>ANSI\/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO\/IEC 11801 Class E<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Dimensions<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 109px;\" width=\"379\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Cable Length<\/td>\n<td>304.8 m | 1000 ft<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Diameter Over Conductor<\/td>\n<td>1.029 mm | 0.0405 in<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Diameter Over Jacket, nominal<\/td>\n<td>6.401 mm | 0.252 in<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Conductor Gauge, singles<\/td>\n<td>23 AWG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Electrical Specifications<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 101px;\" width=\"1345\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Operating Voltage, maximum<\/td>\n<td>80 V<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Remote Powering<\/td>\n<td>Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO\/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Material Specifications<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 75px;\" width=\"269\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Conductor Material<\/td>\n<td>Bare copper<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Insulation Material<\/td>\n<td>Polyolefin<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Jacket Material<\/td>\n<td>PVC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Environmental Specifications<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 54px;\" width=\"403\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Operating Temperature<\/td>\n<td>-20 \u00b0C to +60 \u00b0C (-4 \u00b0F to +140 \u00b0F)<\/td>\n<\/tr>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Flame Test Method<\/td>\n<td>CM<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Packaging and Weights<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 29px;\" width=\"279\">\n<tbody>\n<tr class=\"freeze-row\">\n<td class=\"bkg-blue-gray freeze-column desktop\">Packaging Type<\/td>\n<td>Reel in box<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-title\">Regulatory Compliance\/Certifications<\/h2>\n<div class=\"table-responsive\">\n<table class=\"table\" style=\"height: 109px;\" width=\"830\">\n<thead>\n<tr>\n<td class=\"bkg-blue-gray\">Agency<\/td>\n<td class=\"bkg-blue-gray\">Classification<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"img-td\"><strong class=\"column-title\">ROHS<\/strong><\/td>\n<td class=\"vertical-align\">Compliant<\/td>\n<\/tr>\n<tr>\n<td class=\"img-td\" style=\"text-align: left;\"><strong class=\"column-title\">CHINA-ROHS<\/strong>\u00a0<img decoding=\"async\" class=\"icon-img lazy-load dom-ready loaded\" src=\"https:\/\/www.commscope.com\/globalassets\/digizuite\/33114-logo-rohs-china-e-jpg.jpg\" width=\"21\" height=\"17\" data-src=\"\/globalassets\/digizuite\/33114-logo-rohs-china-e-jpg.jpg\" data-was-processed=\"true\" \/><\/td>\n<td class=\"vertical-align\">Below maximum concentration value<\/td>\n<\/tr>\n<tr>\n<td class=\"img-td\"><strong class=\"column-title\">REACH-SVHC<\/strong><\/td>\n<td class=\"vertical-align\">Compliant as per SVHC revision on www.commscope.com\/ProductCompliance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"ProductSupport\" class=\"Docs-downloads\">\n<div class=\"row\">\n<div class=\"col-md-12\">\n<div class=\"desktop-only\">\n<h1 class=\"section-title\"><span style=\"color: #1aa7ec;\">Product Support<\/span><\/h1>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/extapps.commscope.com\/supportcenter\/\" target=\"_blank\" rel=\"noopener\">Customer and Technical Support, Software\/Firmware, Repair Services<\/a><\/div>\n<\/div>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/www.commscope.com\/support\/training\/\" target=\"_blank\" rel=\"noopener\">Technical Training for CommScope<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"downloads\" class=\"Docs-downloads\">\n<div class=\"row\">\n<div class=\"col-md-12\">\n<div class=\"desktop-only\">\n<h1 class=\"section-title\"><span style=\"color: #1aa7ec;\">Documentation &amp; Downloads<\/span><\/h1>\n<h2 class=\"heading-title\">3rd Party Certification &#8211; Component<\/h2>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/www.commscope.com\/globalassets\/digizuite\/917459-cs31cm-u-utp-cm.pdf\" target=\"_blank\" rel=\"noopener\">CS31CM_U-UTP_CM<\/a><\/div>\n<\/div>\n<h2 class=\"heading-title\">Building Information Modeling (BIM) Objects<\/h2>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"http:\/\/bimobject.com\/en-us\/product?brand=commscope\" target=\"_blank\" rel=\"noopener\">Revit BIM Models<\/a><\/div>\n<\/div>\n<h2 class=\"heading-title\">Product Compliance Documentation<\/h2>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/extapps.commscope.com\/productcompliance?pn=1427254-6\" target=\"_blank\" rel=\"noopener\">Statement of Compliance RoHS\/REACH<\/a><\/div>\n<\/div>\n<h2 class=\"heading-title\">Product Specification<\/h2>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/www.commscope.com\/globalassets\/digizuite\/96614-p360-1427254-6-external.pdf\" target=\"_blank\" rel=\"noopener\">1427254-6 Product specifications<\/a><\/div>\n<\/div>\n<h2 class=\"heading-title\">Technical Publication<\/h2>\n<div class=\"table-row\">\n<div class=\"table-col single\"><a href=\"https:\/\/www.commscope.com\/globalassets\/digizuite\/57711-netconnect-poe-compliance-letter-12-20-19-pdf.pdf\" target=\"_blank\" rel=\"noopener\">Use of NETCONNECT cabling for PoE applications<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Copper Cable, category 6, 4 pair, UTP, CM rated, 23 AWG, 305 m RIB, blue<\/p>","protected":false},"featured_media":15432,"template":"","meta":[],"product_cat":[215,218,219,191,199],"product_tag":[102,107,110,151,194],"class_list":{"0":"post-24510","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-elv","7":"product_cat-218","8":"product_cat-219","9":"product_cat-191","10":"product_cat-199","11":"product_tag-amp","12":"product_tag-cat6","13":"product_tag-commscope","14":"product_tag-151","15":"product_tag-194","17":"first","18":"instock","19":"featured","20":"shipping-taxable","21":"purchasable","22":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24510","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24510\/revisions"}],"predecessor-version":[{"id":24563,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product\/24510\/revisions\/24563"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media\/15432"}],"wp:attachment":[{"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/media?parent=24510"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_cat?post=24510"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.scecl.com\/en\/wp-json\/wp\/v2\/product_tag?post=24510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}