Specifications
| Electrical Specifications | ||
| DC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.05% + 1) | |
| Maximum resolution | 0.1 mV | |
| AC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.7% + 4) true-rms | |
| AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
| Maximum resolution | 0.1 mV | |
| DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(0.2% + 2) | |
| Maximum resolution | 0.1 µA | |
| AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(1.0% + 2) true-rms | |
| Maximum resolution | 0.1 µA | |
| Resistance | Range | 0.1 Ω to 50 MΩ |
| Accuracy | ±(0.2% + 1) | |
| Maximum resolution | 0.1 Ω | |
| Capacitance | Range | 0.01 nF to 9999 μF |
| Accuracy | ±(1% + 2) | |
| Maximum resolution | 0.01 nF | |
| Frequency | Range | 0.5 Hz to 199.99 kHz |
| Accuracy | ±(0.005% + 1) | |
| Maximum resolution | 0.01 Hz | |
| Duty cycle | Maximum duty cycle | 99.9% |
| Accuracy | ±(0.2% per kHz + 0.1%) | |
| Maximum resolution | 0.1% | |
| Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
|
| 80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
|
| Conductance | Maximum conductance | 60.00 nS |
| Accuracy | ±(1.0% + 10) | |
| Maximum resolution | 0.01 nS | |
| Diode test | Range | 2 V |
| Resolution | 0.001V | |
| Accuracy | ±(1% + 1) | |
| Diagnostics and data storage | Peak Min/Max | 250 μS |
| Min/Max/Avg | Yes | |
| Reading hold/Auto (Touch) Hold | Yes | |
| Relative reference | Yes | |
| Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
| Analog bar graph | 32 segments, updates 40/second | |
| Backlight | Two level | |
| Low pass filter (VFD measurements) | Yes | |
| Input Alert™ | Yes | |
| Safety Specifications | ||
| Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
|
| Agency approvals | CE, CSA | |
| Mechanical and General Specifications | ||
| IP rating | IEC 60529: IP67 | |
| Power | Three AA batteries. 800 hours typical, without backlight | |
| Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
| Weight | 698.5 g (with holster) | |
| Warranty | Limited lifetime | |
| Environmental Specifications | ||
| Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
| Storage temperature | -40 °C to + 60 °C | |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
|
| Operating altitude | 2000 m | |
Specifications: Pomona PVLEAD1 MC4 to 4 mm Test Lead Set
| PVLEAD1 | PVLEAD3 | |
| MC4 to 4mm Test Lead Set | MC4 Solar Clamp Meter Test Lead Set | |
| Contact | Brass, Nickel Plated | Brass, Nickel Plated |
| Length | 60” | 36”, 12” |
| Voltage | CAT III 1000V, | CAT III 1000V, |
| CAT IV 600V | CAT IV 600V | |
| Current | 20 amp | 20 amp |
| Standards | IEC 61010-031 | IEC 61010-031 |