Specifications
| Electrical Specifications | ||||
| AC Current via Jaw | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
|||
| Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
|||
| AC Current via Flexible Current Probe | ||||
| Range | 999.9 A / 2500 A (45 Hz – 500 Hz) | |||
| Resolution | 0.1 A / 1 A | |||
| Accuracy | 3% ± 5 digits | |||
| Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
| Position Sensitivity | ||||
![]() |
Distance from Optimum | |||
| i2500-10 Flex | i2500-18 Flex | Error | ||
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5% | |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0% | |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0% | |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
| DC Current | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits | |||
| AC Voltage | ||||
| Range | 600 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
| DC Voltage | ||||
| Range | 600.0 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1% ± 5 digits | |||
| Frequency – Via Jaw | ||||
| Range | 5.0 – 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
|||
| Frequency via Flexible Current Probe | ||||
| Range | 5.0 to 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
|||
| Resistance | ||||
| Range | 600 Ω/6 kΩ/60 kΩ | |||
| Resolution | 0.1 Ω/1 Ω/10 Ω | |||
| Accuracy | 1% ± 5 digits | |||
| Mechanical Specifications | ||||
| Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) | |||
| Weight | 350 g | |||
| Jaw Opening | 34 mm | |||
| Flexible Current Probe Diameter | 7.5 mm | |||
| Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
| Environmental Specifications | ||||
| Operating Temperature | -10°C to +50°C | |||
| Storage Temperature | -40°C to +60°C | |||
| Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
|||
| Operating Altitude | 2,000 meters | |||
| Storage Altitude | 12,000 meters | |||
| EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
|||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||
| Wireless Frequency | 2.4 GHz ISM Band 10 meter range | |||
| Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. |
|||
| Double Insulation Clearance | Per IEC 61010-2-032 | |||
| Double Insulation Creepage | Per IEC 61010-1 | |||
| Agency Approvals | ||||